SPATRAM  18/09/2017
Cooling modes
+ Collaboration diagram for Cooling modes:

Macros

#define LIM_PELTPOW   1000
 Limited Power to the Peltier. More...
 
#define MAX_PELTPOW   1000
 Max Power to the Peltier. More...
 
#define TRTBOTH   2
 Thermoregulation mode: cool and heat. More...
 
#define TRTCOOL   0
 Thermoregulation mode: cool only. More...
 
#define TRTHEAT   1
 Thermoregulation mode: heat only. More...
 

Detailed Description

Macro Definition Documentation

§ LIM_PELTPOW

#define LIM_PELTPOW   1000

Limited Power to the Peltier.

Definition at line 828 of file DAS_Spatramdef.h.

Referenced by OMU_AssignPow(), OMU_ColdOnly(), OMU_HC(), and OMU_HeatOnly().

§ MAX_PELTPOW

#define MAX_PELTPOW   1000

Max Power to the Peltier.

Definition at line 827 of file DAS_Spatramdef.h.

Referenced by OMU_AssignPow().

§ TRTBOTH

#define TRTBOTH   2

Thermoregulation mode: cool and heat.

Definition at line 826 of file DAS_Spatramdef.h.

Referenced by DB_TempHistCB(), and OMU_TemperatureHandle().

§ TRTCOOL

#define TRTCOOL   0

Thermoregulation mode: cool only.

Definition at line 824 of file DAS_Spatramdef.h.

Referenced by DB_TempHistCB(), and OMU_TemperatureHandle().

§ TRTHEAT

#define TRTHEAT   1

Thermoregulation mode: heat only.

Definition at line 825 of file DAS_Spatramdef.h.

Referenced by DB_TempHistCB(), and OMU_TemperatureHandle().